Toshiba TOSVERT VF-MB1 Instruction Manual page 324

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-MB1:
Table of Contents

Advertisement

 Table of output terminal functions 2
Function
Code
No.
30
POLR
31
POLRN
40
RUN
41
RUNN
42
HFL
43
HFLN
44
LFL
45
LFLN
50
FAN
51
FANN
52
JOG
53
JOGN
54
JBM
55
JBMN
56
COT
57
COTN
58
COMOP
59
COMOPN
60
FR
61
FRN
62
RDY1
11
63
RDY1N
64
RDY2
65
RDY2N
68
BR
69
BRN
70
PAL
71
PALN
78
COME
79
COMEN
Function
Braking resistor overload pre-alarm
Inversion of braking resistor overload pre-
alarm
Run/stop
Inversion of run/stop
Heavy fault
Inversion of heavy fault
Light fault
Inversion of light fault
Cooling fan ON/OFF
Inversion of cooling fan ON/OFF
In jogging operation
Inversion of in jogging operation
Operation panel / terminal board operation
Inversion of operation panel/terminal board
operation
Cumulative operation time alarm
Inversion of cumulative operation time alarm
Communication option communication error
Inversion of communication option
communication error
Forward/reverse run
Inversion of forward/reverse run
Ready for operation 1
Inversion of ready for operation 1
Ready for operation 2
Inversion of ready for operation 2
Brake release
Inversion of brake release
Pre-alarm
Inversion of pre-alarm
RS485 communication error
Inversion of RS485 communication error
Action
ON: 50% or more of calculated value of  set
overload protection level
OFF: Less than 50% of calculated value of  set
overload protection level
Inversion of POLR
ON: While operation frequency is output or DC braking is in
operation ()
OFF: Operation stopped
Inversion of RUN
ON: At trip (, , , , , , ,
~, , , , , ,
)
OFF: Other than those trip above
Inversion of HFL
ON: At trip (~, ~, , ~, )
OFF: Other than those trip above
Inversion of LFL
ON: Cooling fan is in operation
OFF: Cooling fan is off operation
Inversion of FAN
ON: In jogging operation
OFF: Other than jogging operation
Inversion of JOG
ON: At terminal board operation command
OFF: Other than those operation above
Inversion of JBM
ON: Cumulative operation time is  or more
OFF: The cumulative operation time is less than 
Inversion of COT
ON: Communication error of communication option occurs
OFF: Other than those above
Inversion of COMOP
ON: Reverse run
OFF: Forward run
(Operation command state is output while motor operation is
stopped. No command is to OFF.)
Inversion of FR
ON: Ready for operation (with ST / RUN)
OFF: Other than those above
Inversion of RDY1
ON: Ready for operation (without ST / RUN)
OFF: Other than those above
Inversion of RDY2
ON: Brake exciting signal
OFF: Brake releasing signal
Inversion of BR
ON: One of the following is turned on
ON POL, POHR, POT, MOFF, UC, OT, LL stop, COT,
and momentary power failure deceleration stop.
Or , , ,  issues an alarm
OFF: Other than those above
Inversion of PAL
ON: Communication error occurred
OFF: Communication works
Inversion of COME
K-36
E6581697
Reference
6.15.4
7.2.2
6.24.11
6.10
5.6
6.24.12
6.33
7.2.2
6.18
7.2.2
6.33