[Example of how to adjust the FM terminal frequency meter]
*
Use the meter's adjustment screw to pre-adjust zero-point.
Operation panel action
LED display
-
MODE
 ⇔
+
MODE
MODE
 Adjusting the meter in inverter stop state
 Adjustment of output current (  = 1 )
If, when adjusting the meter for output current, there are large fluctuations in data during adjustment,
making adjustment difficult, the meter can be adjusted in inverter stop state.
When setting  to  for fixed output 1 (output current 100% equivalent), a signal of absolute
values will be output (inverter's rated current = 100%). In this state, adjust the meter with the  (Meter
adjustment) parameter.
Similarly, if you set  to  for fixed output 2 (output current 50% equivalent), a signal that is sent
out when half the inverter's rated current is flowing will be output through the FM terminal.
After meter adjustment is ended, set  to  (output current).
 Other adjustments (  =  ,  to  ,  ,  ,  ,  to  )
 =  : When fixed output 3 (other than the output current) is set, a signal of the value for other
monitors is fixed at the following values and output through the FM terminal.
100% standard value for each item is the following:
 = 0 , 2 , 12 , 
 = 3 , 4
 = 7
 = 9 to 11
 = 13 ,  ,  ,  : Maximum input value (10V, or 20mA)
 = 18
 = 24 , 25
Displays the output frequency.
 . 
(When standard monitor display selection  is set to  )
The first basic parameter "  " (history function) is displayed.

Turn the setting dial to select  .

Output frequency can be read by pressing the center of the setting
 . 
dial.
Turn the setting dial to adjust the meter.
Note that the meter's indicator changes at this time, but the inverter's
display (monitor) does not change.
 . 
Press the center of the setting dial to save the meter's calibrations.
 and the frequency are displayed alternately.

The display returns to its original indications.
 . 
(When standard monitor display selection  is set to 
[output frequency])
: Maximum frequency ( h )
: 1.5 times of rated voltage
: 2.5 times of rated torque
: Rated load factor
: Maximum value (100.0%)
: 1000x f749