Setting Frequency Command Characteristics - Toshiba TOSVERT VF-MB1 Instruction Manual

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-MB1:
Table of Contents

Advertisement

6.6.2
f107 : Analog input terminal selection(VIB)
f109 : Analog/logic input selection (VIA/VIB)
f201 : VIA input point 1 setting
f202 : VIA Input point 1 frequency
f203 : VIA Input point 2 setting
f204 : VIA Input point 2 frequency
f209 : Analog input filter
f210 : VIB input point 1 setting
f211 : VIB input point 1 frequency
f212 : VIB input point 2 setting
f213 : VIB input point 2 frequency
f216 : VIC input point 1 setting
6
f217 : VIC input point 1 frequency
f218 : VIC input point 2 setting
f219 : VIC input point 2 frequency
f810 : Communication command point selection
f811 : Communication command point 1 setting
f812 : Communication command point 1 frequency
f813 : Communication command point 2 setting
f814 : Communication command point 2 frequency
 Function
To fine adjust the frequency command characteristics for analog input, use the parameters f470 to
f475 . (Refer to section 6.6.4)

Setting frequency command characteristics

Output frequency is adjusted in relation to frequency command according to external analog signals.
VIA and VIB terminals are set to analog input.
f209 analog input filter is effective for eliminating noise from frequency setting circuit. Increase if
operation cannot be done because noise effects stability.
F-14
E6581697

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents