No matter what value the command mode selection and the frequency setting mode selection 1
are set to the control input terminal functions described below are always in operative state.
Reset terminal (valid only for tripping if set for programmable input terminal function)
Standby terminal (when programmed by programmable input terminal functions).
External input tripping stop terminal command (when so set using the programmable input terminal
function)
Coast stop command terminal (if set for programmable input terminal function)
To make changes in the command mode selection and the frequency setting mode selection 1
5
, first stop the inverter temporarily.
(Can be changed while in operation when is set to .)
Priority commands from communications or terminal boards are given priority over .
Preset-speed operation
: Set to (Terminal board operation)
: Valid in all setting values.
Input terminal settings
Assign the following functions to the input terminal to allow switching of the frequency command by turning
the terminal ON/OFF.
106
Each of the following numbers (49, 107) are reverse signals.
A frequency command is set by means of external analog signals.
Terminal board VIC
(VIC terminal: 0 (4) - 20mAdc)
⇒ Refer to section 3.2.2 and 7.3
A frequency command is set by means of external pulse train signals.
Pulse train input
(S2 terminal: 10pps - 20kpps)
⇒ Refer to section 6.6.5
Input terminal function
48
Forced local from communication
Frequency setting mode terminal
board
ON
Enabled during communication
Local (Setting of , )
Terminal board (VIA) enabled
E-12
E6581697
OFF
Communication
setting of