Meter Setting And Adjustment - Toshiba TOSVERT VF-MB1 Instruction Manual

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-MB1:
Table of Contents

Advertisement

3.4

Meter setting and adjustment

 : Meter selection
 : Meter adjustment gain
 Function
Output of 0 - 1mAdc, 0 (4) - 20mAdc, 0 - 10vdc can be selected for the output signal from the FM
terminal, depending on the  setting. Adjust the scale at  .
Use an ammeter with a full-scale 0 - 1mAdc meter.
The  (analog output bias) needs to be adjusted if output is 4 - 20mAdc.
[Parameter setting]
Title
Function
Meter

selection
Meter

adjustment
gain
Adjustment range
0: Output frequency
1: Output current
2: Frequency command value
3: Input voltage (DC detection)
4: Output voltage (command value)
5: Input power
6: Output power
7: Torque
8: -
9: Motor cumulative load factor
10: Inverter cumulative load factor
11: PBR (Braking resistor) cumulative
load factor
12:Stator frequency
13:VIA input value
14:VIB input value
15:Fixed output 1
(output current 100% equivalent)
16:Fixed output 2
(output current 50% equivalent)
17:Fixed output 3
(Other than the output current)
18:RS485 communication data
19:For adjustments (  set value is
displayed.)
20: VIC input value
21: Pulse train input value
22: -
23: PID feedback value
24: Integral input power
25: Integral output power
-
C-13
Supposition output at
Default setting
fsl = 17
Maximum frequency (  )
-
Maximum frequency ( fh )
1.5x rated voltage
1.5x rated voltage
1.85x rated power
1.85x rated power
2.5x rated torque
-
Rated load factor
Rated load factor
Rated load factor
Maximum frequency ( fh )
Maximum input value
Maximum input value
-
-
-
Maximum value (100.0%)
-
Maximum input value
Maximum input value
-
Maximum frequency ( fh )
1000x f749
1000x f749
-
E6581697
3
0
-