(4) Holding the output of signals in ON status
If the conditions for activating the functions assigned to output terminals RY-RC and OUT-NO agree with
and as a result the output of signals is put in ON status, the output of signals is held ON, even if the
conditions change. (Output terminal holding function)
Assign input terminal function 80 to 83 to a logic input terminal available.
Input terminal function
Function No.
Each of the following numbers (81, 83) are reverse signals.
Once output terminal RY-RC or OUT-NO is turned on when the contact input terminal to which one of the
above functions (function 80 to 83) is assigned is ON, output terminal RY-RC or OUT-NO is held ON.
7
Code
Holding of RY-RC terminal
80
HDRY
output
Holding of OUT-NO terminal
82
HDOUT
output
Function
ON: Once turned on, RY-RC are held on.
OFF: The status of RY-RC changes in real
time according to conditions.
ON: Once turned on, OUT-NO are held on.
OFF: The status of OUT-NO changes in real
time according to conditions.