6.7

Operation frequency

6.7.1
f240 : Starting frequency
 Function
[Parameter setting]
f240
6

Starting frequency

The frequency set with  is put out as soon as operation is started.
Use the  parameter when a delay in response of starting torque according to the
acceleration/deceleration time is probably affecting operation. Setting the starting frequency to a
value from 0.5 to 3.0Hz is recommended. The occurrence of an overcurrent can be suppressed by
setting this frequency below the rated slippage of the motor.
Title
Function
Starting frequency
Output frequency (Hz)
Starting frequency 
Operation signal (F-CC)
Adjustment range
0.1-10.0 (Hz)
0
F-22
E6581697
Default setting
0.5
Time
ON
OFF