Toshiba TOSVERT VF-MB1 Instruction Manual
Toshiba TOSVERT VF-MB1 Instruction Manual

Toshiba TOSVERT VF-MB1 Instruction Manual

Traverse control for textile machines
Hide thumbs Also See for TOSVERT VF-MB1:

Advertisement

E6581750
TOSVERT VF-MB1
Traverse control Instruction Manual
~For textile machines~
The technical information in this manual is provided to explain the principal
functions and applications of the product, but not to grant you a license to
use the intellectual property or any other property of Toshiba Schneider
Inverter Corporation or a third party.
© Toshiba Schneider Inverter Corporation 2010
All rights reserved.

Advertisement

loading

Summary of Contents for Toshiba TOSVERT VF-MB1

  • Page 1 The technical information in this manual is provided to explain the principal functions and applications of the product, but not to grant you a license to use the intellectual property or any other property of Toshiba Schneider Inverter Corporation or a third party.
  • Page 2 E6581750 - CONTENTS - Introduction ..........................2 Parameters for setting the traverse function................2 Caution about the use of the traverse control................ 3...
  • Page 3 E6581750 1. Introduction The VF-MB1 has a traverse function useful especially for textile machines. The manual explains about the traverse function. Please read this instruction manual carefully along with the VF-MB1 instruction manual. 2. Parameters for setting the traverse function The parameters in Table 1 are used for traverse operation shown in Figure 1.
  • Page 4 E6581750 3. Caution about the use of the traverse control Note the following information when you use the traverse function. ■ Caution about the use of a potentiometer If an external potentiometer (analog input) is used to set the reference frequency, an error of analog input may occur.
  • Page 5 E6581750 ■ Relationship between traverse reference frequency and output frequency limit The relationship between the traverse reference frequency and the output frequency limit is described. The output signals of lower limit frequency, the upper limit frequency and the low-speed detection during traverse operation are effective to the traverse reference frequency.
  • Page 6 E6581750 The traverse operation signal can be sent from inverter to external devices. Assign the function No. 124 / 125 [inverse] (traverse in progress) and 126 / 127 [inverse] (traverse deceleration in progress) to the output terminals. Output terminal selection parameter: f130 to f138 Example: Output the raverse in progress signal from the RY-RC terminal.