6.7.2
Run/stop control with frequency setting signals
f241 : Operation starting frequency
f242 : Operation starting frequency hysteresis
 Function
The Run/stop of operation can be controlled simply with frequency setting signals.
[Parameter setting]
Title
Operation starting frequency
f241
Operation starting frequency hysteresis
f242
Output frequency [Hz]
 +


 -

Function

0
A
B
F-23
Adjustment range
0.0- fh (Hz)
0.0- fh (Hz)
When the frequency command signal
reaches the B point, the inverter
operates.
When decelerating, operation stops
when the frequency setting signal is less
than point A.
100% Frequency command value
E6581697
Default setting
0.0
0.0