12. Specifications

12.1 Models and their standard specifications

 Standard specifications
Item
Input voltage class
Applicable motor (kW)
Type
Form
Capacity (kVA) Note 1)
Output current (A)
Note 2)
Output voltage Note 3)
Overload current rating
Voltage-frequency
Allowable fluctuation
Required Power supply
capacity (kVA) Note 5)
Protective method (IEC60529)
Cooling method
Color
Built-in filter
Item
Input voltage class
Applicable motor (kW)
Type
Form
Capacity (kVA) Note 1)
Output current (A)
Note 2)
Output voltage Note 3)
Overload current rating
Voltage-frequency
Allowable fluctuation
Required Power supply
capacity (kVA) Note 5)
Protective method (IEC60529)
Cooling method
Color
Built-in filter
Note 1. Capacity is calculated at 220V for the 240V models, at 440V for the 500V models.
Note 2. It is a value when the inverter overload characteristic selection (parameter aul) is the constant torque characteristic.
Value in ( ) for the variable torque characteristic. Input AC reactor (ACL) is needed when output current is used by ().
The output current must be reduced according to the PWM carrier frequency and ambient temperature.
(Refer to section 6.14)
Note 3. Maximum output voltage is the same as the input voltage.
Note 4. At 180V-264V for the 240V models, at 342V-550V for the 500V models when the inverter is used continuously (load of
100%).
Note 5. Required power supply capacity varies with the value of the power supply side inverter impedance (including those of
the input reactor and cables).
0.2
0.4
2002PL
2004PL
0.6
1.3
1.5
3.3
(1.9)
(3.7)
150%-60 seconds, 200%-0.5 second (120%-60 seconds, 165%-0.5 second) Note 2)
0.8
1.4
0.4
0.75
1.5
4004PL
4007PL
4015PL
1.1
1.8
3.1
1.5
2.3
4.1
(2.1)
(3.0)
(5.4)
150%-60 seconds, 200%-0.5 second (120%-60 seconds, 165%-0.5 second) Note 2)
1.6
2.6
4.7
Specification
1-phase 240V class
0.75
VFMB1S
2007PL
1.8
4.8
(6.0)
3-phase 200V to 240V
1-phase 200V to 240V - 50/60Hz
Voltage 170 to 264V Note 4), frequency ±5%
2.3
IP20
Forced air-cooled
RAL7016
EMC filter
Specification
3-phase 500V class
2.2
4.0
5.5
VFMB1
4022PL
4037PL
4055PL
4.2
7.2
11
5.5
9.5
14.3
(6.9)
(11.9)
(17.0)
3-phase 380V to 500V
3-phase 380V to 500V - 50/60Hz
Voltage 323 to 550V Note 4), frequency ±5%
6.3
10.1
15.2
IP20
Forced air-cooled
RAL7016
EMC filter
L-1
E6581697
1.5
2.2
2015PL
2022PL
3.0
4.2
8.0
11.0
(10.0)
(13.7)
4.0
5.4
7.5
11
15
4075PL
4110PL
4150PL
13
21
25
17.0
27.7
33.0
(23.0)
(33.0)
(40.0)
19.6
26.9
34.9
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents