De-rating of rated current
[Single phase 240V class]
In case of parameter aul = 1 (Constant torque characteristic (150%-60s)) setting.
Ambient
VFMB1S-
temperature
40  C or less
2002PL
40  50  C
50  60  C
40  C or less
2004PL
40  50  C
50  60  C
40  C or less
2007PL
40  50  C
50  60  C
40  C or less
40  50  C
2015PL
50  60  C
40  C or less
2022PL
40  50  C
50  60  C
In case of parameter aul = 2 (Variable torque characteristic (120%-60s)) setting.
Ambient
VFMB1S-
temperature
2002PL
40  C or less
2004PL
40  C or less
2007PL
40  C or less
40  C or less
2015PL
40  C or less
2022PL
PWM carrier frequency (Parameter f300 )
2.0k - 4.0 kHz
4.1k - 12.0 kHz
1.5 A
1.5 A
1.5 A
1.4 A
1.2 A
1.1 A
3.3 A
3.3 A
3.3 A
3.0 A
2.6 A
2.3 A
4.8 A
4.8 A
4.8 A
4.3 A
3.8 A
3.4 A
8.0 A
8.0 A
8.0 A
7.2 A
6.4 A
5.6 A
11.0 A
11.0 A
11.0 A
9.9 A
8.8 A
7.7 A
PWM carrier frequency (Parameter f300 )
2.0kHz
2.1k - 4.0 kHz
1.9 A
1.5 A
3.7 A
3.3 A
6.0 A
4.8 A
10.0 A
8.0 A
13.7 A
11.0 A
F-33
E6581697
12.1k - 16.0 kHz
1.5 A
1.3 A
1.0 A
3.3 A
2.8 A
2.2 A
4.8 A
4.1 A
3.1 A
8.0 A
6.8 A
5.2 A
11.0 A
9.4 A
7.2 A
4.1k - 12.0 kHz 12.1k - 16.0 kHz
1.5 A
1.5 A
3.3 A
3.3 A
4.8 A
4.8 A
8.0 A
8.0 A
11.0 A
11.0 A