Chapter 8 Configuring Hardware and Utilities
8.3.9 ASR&R Submenu
Settings for booting control are configured on the [ASR&R] submenu.
Item
O/S Boot Timeout
O/S Boot WD Time (min)
O/S Boot WD Behavior
ASR&R Boot Delay (min)
Power Cycle Delay
Boot Retry Counter
Diagnostic System
Next Boot Uses
Diagnostic Lan Device
Temperature Monitoring
248
table: Items on the ASR&R Submenu
Settings
• Enabled
Set whether or not to enable the "OS Boot
Monitoring" function. The system restarts
• Disabled(initial
automatically in case of stopping booting the OS.
value)
This can be set on the ServerView.
Note:
Set the time out value by the minute.
• 100(initial value)
• 0 ~ 100
• Continue
Set the behavior in time out.
(initial value)
• Reset
• Power Cycle
Set the standby time between shutdown and
• 2(initial value)
• 0 ~ 30
restarting by the minute. When the standby time
passes, the system is restarted.
Set the time between power off and on.
• 5(initial value)
• 0 ~ 15
Set a maximum number of retrying OS booting.
• 3(initial value)
• 0 ~ 7
Disabled
This value cannot be changed.
(unchangeable)
Boot Option
This value cannot be changed.
(unchangeable)
Use Boot Order
This value cannot be changed.
(unchangeable)
Disabled
Set whether being possible to turn on the server
(unchangeable)
outside the range of temperature conditions (10 to 35
degrees C).
Description
Be sure to set "Disabled" when the
ServerView is not installed to the OS. If you
set "Enabled" in above case, unintended
power-off or restarting may occur.
Even with the ServerView, when the system is
booted with the ServerStart CD-ROM or DOS
floppy disk, be sure to set "Disabled". If you
set "Enabled" in above case, unintended
power-off or restarting may occur.
To set this function, refer to "ServerView
User's Guide" to understand the
specifications and operational procedures.