Fujitsu Primergy RX600 S2 User Manual page 266

Hide thumbs Also See for Primergy RX600 S2:
Table of Contents

Advertisement

Chapter 9 Operation and Maintenance
■ Error Messages during Installation
The following error messages may appear during installation using ServerStart. Check the corrective
action against the relevant error.
"WzDiskAdmin: System Error! ......................, Last Error: The device is not
ready." appears
Optional SCSI devices (e.g., hard disk cabinet, MO disk unit, or DAT unit) may be connected.
Disconnect the optional SCSI devices and perform installation again. Connect the optional devices after
the installation completes.
"WzDiskAdmin: Partition detected! Please delete all partition before starting
Configuration" appears
Run the guided or preconfiguration mode again. Check [Delete all partitions on the displayed disk] in
the disk wizard.
"WzRaid: RAID arrays detected! Please delete all RAID arrays before starting
Configuration" appears
Use the ServerStart floppy disk you have created. Check [Delete existing RAID array] or select [Use
existing array] in the RAID wizard.
"Operating System not found" appears when the system restarts after file
copy from the CD-ROM
The following problems should be considered. Check the settings.
• The array controller card comes later than the onboard SCSI in order of device startup.
• The Active flag is specified.
"Missing Operating System" appears during installation
The installation partition size may be too large. Specify the installation partition size correctly.
For details on the installation partition size, refer to "2.3.1 Installation Partition Size" ( Pg.49).
"Error 1920. Service (PXE Services) failed to start" appears during
preconfigured installation
The system installed with the preconfigured settings (PXE server) may not be connected to the network.
Check the LAN cable connection and click [Rerun].
266

Advertisement

Table of Contents
loading