6
To replace the memory module, open outward the retention clips on both sides
of the slot.
7
Open the retention clips on both sides of the slot and insert the memory
module.
Align the notch on the memory module with the memory slot and insert the module vertically in
the slot.
When the module is correctly inserted, the retention clips on both sides will close. Then, check
that the memory module is securely fastened.
If the retention clips are not securely closed, press them closed with your fingers.
8
Attach the memory cover to the memory board.
To attach it, simply reverse the removal procedure.
9
Install the memory board in the server.
To attach it, simply reverse the removal procedure.
10
Install the top cover.
• Make sure not to open the clips outward too quickly because the
memory module may pop up, which could cause damage.
• An improperly engaged memory module could cause a fire. Do not
insert the memory module on the wrong side.
PRIMERGY RX600 S2 User's Guide