C2
INSTALLATION MANUAL
CAUTION: ALWAYS remove power to the C2 along with any other
electronics equipment prior to making any connections to or from the
C2. Set the Power Switch on the back of the C2 to the OFF
position prior to making connections.
C2 to PVSE Electronic Volume Control Precision Panel
When connecting the C2 to a PVSE Precision Panel, use an RJ-45 to pigtail connector.
Connect the Blue Override (pin 1) wire to "+" of the C2's VCO connector.
Connect the White/Blue Ground wire (pin 2) to the "-" of the C2's VCO connector. Plug the
RJ-45 into the OVERRIDE IN connector on the PVSE. See the PVSE Installation manual for
additional wiring for the PVSE and Electronic Volume Controls.
CAUTION: ALWAYS remove power to the C2 along with any other
electronics equipment prior to making any connections to or from the
C2. Set the Power Switch on the back of the C2 to the OFF
position prior to making connections.
C2
Blue
Wh/Blue
Orange
Wh/Orange
Green
Wh/Green
Brown
Wh/Brown
Figure 3-3: C2 to PVSE Electronic Volume Control Precision Panel Wiring Pinout
Page 30
2
Figure 3-2: C2 to VSE2 Wiring Pinout
Override
Ground
N/C
N/C
N/C
N/C
Cat-5
N/C
N/C
Blue
Override
White/Blue
IR OUT
Orange
IR IN
White/Orange
N/C
Green
N/C
+12V
White/Green
Brown
GND
RJ-45 to
N/C
White/Brown
Pigtail
Standard ELAN RJ-45 Pin-Out
PIN # COLOR CODE
1
BLUE
2
WHITE/BLUE
3
ORANGE
4
WHITE/ORANGE
TAB
5
GREEN
6
WHITE/GREEN
7
BROWN
8
WHITE/BROWN
CABLE
PVSE
Override IN
OVERRIDE
OVERRIDE
IN
OUT
© ELAN Home Systems 2009 • All rights reserved.
E L A N H O M E S Y S T E M S
VSE2
Standard ELAN RJ-45 Pin-Out
PIN # COLOR CODE
1
2
3
4
TAB
5
6
7
8
CABLE
BLUE
WHITE/BLUE
ORANGE
WHITE/ORANGE
GREEN
WHITE/GREEN
BROWN
WHITE/BROWN