2GN/2GP/2GR-2

(2) Detaching and refitting the scanner wires

Take the following procedure when the scanner wires are broken or to be replaced.
NOTE
When fitting the wires, be sure to use those specified below.
Machine front: (P/N: 302GR17110), gray
Machine rear: (P/N: 302GR17100), black

Fitting requires the following tools

Two frame securing tools
Two scanner wire stoppers (P/N 3596811)
Procedure
Detaching the scanner wires
1. Remove the exposure lamp (see page 1-5-
12).
2. Remove the clip holder.
3. Open the front cover and left cover 1.
4. Remove four screws and remove front left
cover.
5. Remove the screw and pin and then remove
the left upper cover.
1-5-14
Front left cover
Figure 1-5-31
Pin
Screw
Figure 1-5-32
Clip holder
Left upper cover