(6) Detaching and refitting the fuser unit thermistor 1 and 2

Follow the procedure below to replace the fuser unit thermistor 1 and 2.
Procedure
1. Remove the fuser unit (see page 1-5-30).
2. Remove the upper fuser cover (see page 1-
5-31).
3. Release the stopper of the fuser unit ther-
mistor 1.
4. Remove the connector and remove the
fuser unit thermistor 1.
5. Replace the fuser unit thermistor 1 and
install the thermistor to fuser unit.
6. Remove the press roller and fuser heater
(see page 1-5-32 and 33).
7. Remove the heat roller (see page 1-5-34).
8. Remove the screw and the connector, and
then remove the fuser unit thermistor 2.
9. Replace the fuser unit thermistor 2 and
install the thermistor to fuser unit.
10. Refit the heat roller, fuser heater, press roller
and upper fuser cover.
11. Refit the fuser unit.
Stopper
Fuser unit thermistor 1
Figure 1-5-71
Fuser unit thermistor 2
Figure 1-5-72
2GN/2GP/2GR-1
Connector
Connector
1-5-35