Disconnect Time - Panasonic KX-TD816 Installation Manual

Digital super hybrid system
Hide thumbs Also See for KX-TD816:
Table of Contents

Advertisement

45 0
CO Line Programming
414
Disconnect
Time
Description
Determines the amount of time between successive accesses to the
same CO line, if "Disable" is selected in program [413] "Flash
Time." The flash feature provides a released loop during the
programmed
time.
Selection
l
CO line group (TRG) number:
1 through 8, *
( * =all CO
line groups)
l
Time (seconds):
1.5 /
4.0
Default
All CO line groups - 1.5 s
Programming
1.
2.
3.
4.
5.
6.
Conditions
7.
Repeat steps 4 through 6.
8.
Press
END.
Enter 414.
Display: TRG Discnct Time
Press
NEXT.
Display
:
TRK GRP NO?->
Enter a CO
line group number.
To
program CO line group number 1, you can also press NEXT.
Display example: TRG1:1.5sec
Keep pressing
SELECT
until the desired time is displayed.
Press
STORE.
To program another CO line group, press
NEXT
or
PREV,
or
SELECT
and the desired CO
line group number.
l
The disconnect time must be longer than the requirements of the central
office or the host PBX.
l
To assign all CO line groups to one selection, press the * key at step 3.
In this case, the display shows the contents programmed for CO line
group 1.
l
Program [401] "CO Line Group Assignment" is used to assign each CO
line to a CO line group.
Feature References
Section 3, Features,
Flash
System Programming
4-93

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-td1232

Table of Contents