Error Code And Strings - Canon imageRUNNER 2530 Service Manual

Imagerunner 2530/2520/2525 series;
Hide thumbs Also See for imageRUNNER 2530:
Table of Contents

Advertisement

2
Technology > Embedded RDS > Troubleshooting > Error code and strings
No.2
A communication test results NG! even if network setting is set properly.
Cause: No proper firmware has been installed, or E-RDS settings have not been completed.
Remedy: The following points should be checked.
1) Check the firmware compatibility of device.
2) Check network conditions such as proxy server settings and so on.
3) Check E-RDS setting.
a) Check the communication log from COM-LOG.
b) If RGW-ADR or RGW-PORT setting has changed, restore default value by Servicemode
> #CLEAR > ERDS-DAT.
c) If CA certificate file has changed, restore the original certificate file installed at the factory
shipment to the device by using a service support tool.
No.3
There was a log, indicating "
Network is not ready, try later
details of COM-LOG list.
Causes: A certain problem occurred in networking.
Remedy: Check and take actions mentioned below.
1) Check networking conditions and connections.
2) Turn on the power supply of a device and perform a communication test (Servicemode >
#E-RDS > COM-TEST about 60 seconds later.
No.4
"Unknown error" is displayed though a communication test has done
successfully.
Causes: A certain problem was in the server side, or possibly a network load has been
added.
Remedy: The following points should be checked.
1) Change data transmission schedules, and then see how things going.
2) Try again after a period of time. If the same error persists, check the UGW status with a
network and UGW administrator.
2
Technology > Embedded RDS > Troubleshooting > Error code and strings

Error code and strings

The error information appeared to a communication test log is as follows.
( Here, "server" means UGW)
By error list, error No.1 and No.2 display only an error character strings.
Error No 3 henceforth, these are displayed in the following form.
[*][Error character strings] : [Method name] [Server side detailed error]
*: Error character strings head "*" is added to the error generated by the communication
test.
No. Code Error character
1
0500
(No.22)" in error
0003
2
0xxx
00f2
3
8xxx
2001
4
8xxx
200A
5
8xxx
2002
6
8xxx
2014
7
8xxx
201E
Causes
strings
SUSPEND:
The communication test
Communication test
had not been performed,
is not performed.
though E-RDS is enabled.
Event Registration
Processing (event
is Failed
processing) within the
device has failed.
URL Scheme
The header of the URL of
error(not https)
the registered UGW is not
in https format.
Server connection
Displayed in the event of
error
a TCP/IP communication
fault. Also displayed when
an attempt is made at
communication with the
device IP address not set.
URL server
A URL different to that
specified is illegal
specified by the UGW has
been set.
Proxy connection
Could not connect to proxy
error
server due to improper
address.
Proxy
Proxy authentication is
authentication error
failed.
2-79
Remedy
Select and perform Servicemode >
#E-RDS > COM-TEST.
Turn the device OFF/ ON. If the error
persists, replace the device system
software. (Upgrade)
Check that the value of Service mode
> #E-RDS > RGW-ADR is https://a01.
ugwdevice.net/ugw/agentif010.
Check the network connection, as per
the initial procedures described in the
troubleshooting.
Check that the value of Service mode
> #E-RDS > RGW-ADR can be https://
a01.ugwdevice.net/ugw/agentif010.
Check proxy server address and re-
enter as needed.
Check the user name and password
required in order to login to the proxy,
and re-enter as needed.
2-79

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents