2
Technology > Embedded RDS > Service cautions
Com-Log Report
The report output of the communication error logging information on five affairs can be carried
out.
#REPORT > #REPORT OUTPUT > ERDS COM LOG LIST
Output sample
01/17 2009 10:14
****************************
*** E-RDS-COM-LOG ***
****************************
No.01 DATE 05 18 2009 TIME 03:21 CODE 05000003
Information
SUSPEND: Communication test is not performed.
No.02 DATE 05 18 2009 TIME 03:21 CODE 00000000
Information
SUNSEND: mode changed.
No.03 DATE 05 18 2009 TIME 03:18 CODE 05000003
Information
SUSPEND: Communication test is not performed.
No.04 DATE 05 18 2009 TIME 03:18 CODE 00000000
Information
SUNSEND: mode changed.
No.05 DATE 05 18 2009 TIME 01:56 CODE 05000003
Information
SUSPEND: Communication test is not performed.
2
Technology > Embedded RDS > Service cautions
Service cautions
After performing the following service activities it is necessary to perform Service mode
#CLEAR > ERDS-DAT and #E-RDS.
Failure to do so will result that the counter transmitting value to the UGW may become
unusual.
•
System upgrade
•
HDD format and system installation
•
COPIER > Function > Clear > MN-CONT
Also, after replacing the main controller board, all settings must be reprogrammed.
The following settings in service mode must not be change unless there are specific
instructions to do so. Changing these values will cause error in communication with UGW.
Service mode
#E-RDS > RGW-PORT
443
#E-RDS > RGW-ADDRESS
https://a01.ugwdevice.net/ugw/agentif010
2-82
Default
T-2-45
T-2-45
2-82