When a license option is displayed in Procedure (4), 001 1 is displayed. The last "1" shows
that the license is validated by license authentication.
After the license is erased, the last number is changed to "2".
When the option is standard, the last number shows "3" which means disable for license
transfer.
Details about the last number:
1: The function is validated.
2: The function is invalidated, or a license is transferred.
3: The function is invalidated, or the license does not exist.
8
Service Mode > Details of Service Mode > #E-RDS > Configuration
8
Service Mode > Details of Service Mode > #E-RDS > Configuration

#E-RDS

Configuration

Settings related to e-RDS are described below.
Item
Default
Setting range
E-RDS
0
0 or 1
SWITCH
RGW-
URL of UGW Character string
ADDRESS
length:129byte
(including NULL,
one-byte codes only)
RGW-PORT 443
1-65535
CNT-DATE
CNT-INTV
24
1-168 (on a weekly
basis)
COM-TEST
COM-LOG
SCALLCMP
8-38
Description
e-RDS OFF/ON setting (0:OFF / 1:ON)When
used (ON), the counter information and error
information are sent to UGW.Default: 0 (OFF)
URL of UGWDefault: URL of actual
UGWCharacter string length: 129 bytes (including
NULL, one-byte codes only)
Port No. of UGW Default: 443Setting range: 1 to
65535
Setting of the date of sending the counter
information to the server (Valid after input of
license).
Set the start date of the schedule to send the
counter information to the server using a third
party expansion function of E-RDS.
Refer to the user mode date setting.
(12 digits: YYYYMMDDHHMM)
YYYY: Year MM: Month DD: Day
HH: Hour MM: Minute
Setting of the interval of sending the counter
information to the server (Valid after input of
license).
Set the interval of sending the counter information
to the server using a third party expansion
function of E-RDS.
Execution of communication test An attempt
is made to connect to UGW, judges whether
connection is successful, and displays "COM-
TEST OK" or "COMTEST NG" as the judgment
result.
Details of communication test result. The log of
errors in communication with UGW is displayed.
The error information includes the error occurrence
time, error code, and details of the error.Maximum
log count: 5Error information length: Max. 128
characters (excluding NULL)
Repair completion process (call button function)
Used when the service personnel has completed
the requested repair.
8-38