Removing The Adf Scan Glass; Action To Take After Replacing The Adf Scan Glass - Canon imageRUNNER 2530 Service Manual

Imagerunner 2530/2520/2525 series;
Hide thumbs Also See for imageRUNNER 2530:
Table of Contents

Advertisement

4
Parts Replacement and Cleaning > Main Units/Parts > Removing the ADF Scan Glass > Action to Take after Replacing the ADF Scan Glass

Removing the ADF Scan Glass

1) Open the platen cover (platen board cover/ADF).
2) Remove the glass retainer.
2 screws
3) Remove the ADF scan glass.
x2
4
Parts Replacement and Cleaning > Main Units/Parts > Removing the ADF Scan Glass > Action to Take after Replacing the ADF Scan Glass
CAUTION:
When removing the ADF scan glass, take care not to touch the glass surface with
your fingers.
Soils on the glass surface may cause white/black lines on images.
If the glass surface is soiled, clean them with a lint-free paper moistened with
alcohol.
Be sure to install the ADF scan glass with its seat facing front left.
F-4-67
F-4-67

Action to Take after Replacing the ADF Scan Glass

1.Enter the service mode, and then select the following:
SCAN > READER > FUNCTION > CCD > DF-WLVL1/2/3/4 (DF white level adjustment)
1) Place a sheet of paper that the user usually uses on the platen glass, enter the service
mode, and then select SCAN > READER > FUNCTION > CCD > DFWLVL1.
Read the white level in the BOOK mode. (Check the transparency of the glass for BOOK
mode.)
2) Place a sheet of paper that the user usually uses on the DF, enter the service mode, and
then select SCAN > READER > FUNCTION > CCD > DF-WLVL2.
Read the white level in the DF mode (stream reading). (Check the transparency of the
glass for stream reading.)(Read both sides of the chart.)
4-33
F-4-68
F-4-68
4-33

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents