INSTALLATION REQUIREMENTS

3.1.3 MINIMUM SPACE REQUIREMENTS

Place the copier near the power source, providing clearance as shown below. The
same amount of clearance is necessary when optional equipment is installed.
Copier + Finisher + LCT
400 mm
Copier + Finisher
400 mm

3.1.4 POWER REQUIREMENTS

!
CAUTION
1. Make sure the plug is firmly inserted in the outlet.
2. Avoid multi-wiring.
3. Do not set anything on the power cord.
Input voltage level:
1.
NEMA 6-20R
A294/A295
CÓPIA NÃO CONTROLADA
200 mm
555 mm
200 mm
555 mm
North America (NEMA 6-20R Receptacle)
220~240V (+/-10%), 60 Hz: More than 10A (A294)
220~240V (+/-10%), 60 Hz: More than 12A (A295)
Europe/Asia (Receptacle market specific)
220~240V (+/-10%), 50/60 Hz: More than 10A (A294)
220~240V (+/-10%), 50/60 Hz: More than 12A (A295)
NOTE: For USA installations, standard 220V (+/-10%)
wall voltage is acceptable.
3-2
CÓPIA NÃO CONTROLADA
Rev. 6/2000
30 mm
A294I022.WMF
30 mm
A294I023.WMF
SM