PAPER EXIT/DUPLEX UNIT
6.10 PAPER EXIT/DUPLEX UNIT
6.10.1 EXIT SENSOR REPLACEMENT
[B]
[A]
1. Pull out the fusing and exit unit.
2. Remove the sensor bracket [A] with the sensor (1 screw, 1 connector, and 2
clamps).
3. Replace the exit sensor [B].
NOTE: When putting back the sensor bracket, run the cable through the cutout [C]
to slacken the cable.
A294/A295
CÓPIA NÃO CONTROLADA
[C]
6-96
CÓPIA NÃO CONTROLADA
A294R601.WMF
SM