4.8.4 LEDS
SICU
Number
Blinking: Normal
LED101
Stays on or off: CPU defective
LED102
Off: Normal
LED103
Off: Normal
LED104
Blinking: Normal
BCU
Number
LED601
Off: Normal
(Green)
Stays on: While downloading the flash memory card.
LED602
Blinking: Normal
(Red)
Stays on: While downloading the flash memory card.
I/O Board
Number
Turns on when motor/solenoid drive signal is sent from
LED1
the BCU to IOB (Normally on).
PSU
Number
LED1
On: Normal
On: Stand-by
LED2
Off: Energy saver mode
On: Stand-by
LED3
Off: Energy saver mode
ADF Main Board
LED100
LED101
❍
—
❍
—
❍
❍
—
—
❍
—
❍
❍
✰
—
✰
—
—
—
✰
✰
✰
—
✰
✰
✰
—
✰
—
SM
CÓPIA NÃO CONTROLADA
Monitored Signal
Monitored Signal
Monitored Signal
Monitored Signal
LED102
—
Entrance Sensor Jam
—
Registration Sensor Jam
—
Exit Sensor Jam
❍
Inverter Sensor Jam
Jammed paper not removed:
❍
Between entrance sensor + registration sensor
❍
Jammed paper not removed: On the exposure glass
—
Feed-in Motor Abnormal
—
Transport Motor Abnormal
✰
Feed-out Motor Abnormal
—
Pick-up Motor Abnormal
✰
Bottom Plate Motor Abnormal
✰
DF Position (Open)
✰
APS Sensor ON
—
Normal
4-91
CÓPIA NÃO CONTROLADA
USER PROGRAM MODE
✰
❍: ON
: Blinking
A294/A295