LASER UNIT
6.4.4 LASER SYNCHRONIZATION DETECTOR REPLACEMENT
1. Turn off the main power switch and unplug the machine.
2. Remove the ground plate [A] (1 screw).
3. Remove the detector cover [B] (2 screws).
4. Replace the laser synchronization detector [C] (1 screw, 1 connector).
A294/A295
CÓPIA NÃO CONTROLADA
6-32
CÓPIA NÃO CONTROLADA
[B]
[A]
[C]
A294R105.WMF