SENSOR REPLACEMENT

4.4 SENSOR REPLACEMENT

4.4.1 STACK HEIGHT 1, 2 AND EXIT GUIDE OPEN SENSOR

1. Remove the upper cover.
Stack Height Sensors 1 and 2
2. Remove the sensor feeler [A] (1 screw).
3. Remove the sensor bracket [B] (1 screw).
4. Replace the stack height sensor 1 [C] or 2 [D] (1 connector each).
Exit Guide Open Sensor
2. Remove the sensor bracket [E] (1 screw).
3. Replace the exit guide open sensor [F] (1 connector).
A294/A295
CÓPIA NÃO CONTROLADA
[B]
[C]
[A]
8-26
CÓPIA NÃO CONTROLADA
[D]
[E]
[F]
B302R509.WMF