4.7 ROM HISTORY

4.7.1 FIRMWARE MODIFICATION HISTORY

B302 FINISHER FIRMWARE MODIFICATION HISTORY
DESCRIPTION OF MODIFICATION
First Production
Corrects the following:
• SP6-120 Staple Jogger Adjustment was missing. The
staple jogger positions for each paper size can be
adjusted by SP6-120. This modification becomes
effective when the mainframe firmware is updated to
version 7.23.2 (F) or later.
6-120
Staple Jogger Adjustment
1
A3
2
B4
3
A4 L
4
A4 S
5
B5 L
6
B5 S
7
DLT L
8
LG L
9
LT L
10
LT S
11
Others
Corrects the following:
• Door open is indicated after a staple job
• After a staple job, the Staple Unit does not move to
the staple supplying position in the staple end
condition.
• Stapled sheets of paper fed out incorrectly when the
interrupt function is used during printing.
• (A295 w/B302 only) Mistake-stapling, mistake-
jogging, R2 Jam, R6 Jam.
Corrects the following:
(A295 w/B302 only) Tab paper stack failure, exit
paper jam in different paper length paper shift.
SM
CÓPIA NÃO CONTROLADA
S
Adjusts the staple jogger positions for
each paper size.
8-35
CÓPIA NÃO CONTROLADA
ROM HISTORY
FIRMWARE
SERIAL NUMBER
LEVEL
B3025103 B
From 1st production
B3025103 C
February '00
production
+1.5 ~ -1.5
0.5 mm/step
0 mm
B3025103 D
March '00
production
B3025103 E
April '00 production