Drum Unit; Process Control - Gestetner A294 Service Manual

Table of Contents

Advertisement

DRUM UNIT

2.5 DRUM UNIT

2.5.1 PROCESS CONTROL

Overview
The drum potential will gradually change because of the following factors.
• Dirty charge corona casing and grid plate
• Changes in drum sensitivity
To maintain good copy quality, the machine does the following just after the main
switch has been turned on (if the fusing temperature is less than 100 °C and SP3-
901 is on).
1) Potential Sensor Calibration
2) V
Adjustment
SG
3) V
(Grid Voltage) Adjustment
G
4) LD Power Adjustment
5) V
Update
REF
This process is known as 'Process Control Initial Setting'. The rest of this section
will describe these steps in more detail.
Processes 1, 3, and 4 in the above list compensate for changes in drum potential.
Processes 2 and 5 are for toner density control; see the "Toner Density Control"
section for more details.
A294/A295
CÓPIA NÃO CONTROLADA
2-38
CÓPIA NÃO CONTROLADA
SM

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

A295

Table of Contents