Develop ineo 250 Service Manual Field page 520

Hide thumbs Also See for ineo 250:
Table of Contents

Advertisement

Field Service Ver. 1.0 Aug. 2005
MODE
Bit:
464
Bit
Feature
7
Select RAW port number
(last 8 bits). *
6
5
4
3
2
1
0
NOTE
• The features with (*) are settable by users. *: Screen setting of IT Series Agent
MODE
Bit:
465
Bit
Feature
7
Select RAW port number
(first 8 bits). *
6
5
4
3
2
1
0
NOTE
• The features with (*) are settable by users. *: Screen setting of IT Series Agent
Factory setting bit
7 6 5 4
3 2 1 0
1 0 0 0
1 1 0 0
Logic
0
1
Bit 7-0:
00000000 Not available
10001100 9100
11111111 65535
Factory setting bit
7 6 5 4
3 2 1 0
0 0 1 0
0 0 1 1
Logic
0
1
Bit 7-0:
00000000 0
00100011 9100
11111111 65535
HEX:8C
Description
|
|
HEX:23
Description
Most significant bit for
mode 464
|
|
11. Soft Switch List