Paper Exit Roll 1; Paper Exit Roll 2 - Develop ineo 250 Service Manual Field

Hide thumbs Also See for ineo 250:
Table of Contents

Advertisement

Field Service Ver. 1.0 Aug. 2005
7.3.41

Paper Exit Roll 1

1. Remove the Fusing Unit.
37
[1]
7.3.42

Paper Exit Roll 2

1. Remove the Fusing Unit.
37
[1]
[2]
[3]
[5]
2. Remove four screws [1] and four Exit
[2]
Rolls 1 Assy [2].
4040F2C641DA
3. Remove the Exit Roll 1 [3].
[3]
4040F2C642DA
2. Snap off the C-clip [1] and remove
the Fusing Entrance Guide Plate [2].
4040F2C625DA
3. Remove two shoulder screws [3], the
screw [4], and the Exit Rolls 2 Assy
[4]
[5].
[3]
4040F2C643DA
7. Other
91