Field Service Ver. 1.0 Aug. 2005
(3) POP3 Password
Functions
• To set the POP3 password.
Use
• To enter the POP3 password.
1. Touch the [POP3 Password].
Setting/
2. Touch [New Password], enter the password, and then touch [Enter].
Procedure
3. Touch [Confirm New Password], enter the password once again, and then touch
[Enter].
(4) Auto-RX Check
Functions
• To set intervals, at which a check is made by connecting to the POP3 server.
Use
• To change the intervals, at which a check is made by connecting to the POP3 server.
• The default setting is "Check OFF".
• Setting range: 1 to 99 M
Setting/
1. Touch the [Auto-RX Check].
Procedure
2. Enter the value from the 10-Key Pad and touch [Enter].
3. Select [Check OFF] to select not to make the auto check.
F. Mail/Scan Settings
(1) E-Mail Mode
<TX Size (Max.)>
Functions
• To set the upper limit of the size of the document to be sent.
Use
• To set the default upper limit of the size of the document for Internet Fax.
• The default setting is "11x17".
Setting/
Procedure
<TX Quality (Max.)>
Functions
• To set the upper limit of the image quality to be sent.
Use
• To set the upper limit of the image quality to be sent.
• The default setting is "600 dpi".
Setting/
Procedure
<Coding Method>
Functions
• To set the coding method for the data to be sent.
Use
• To set the coding method for the data to be sent.
• The default setting is "MH".
Setting/
Procedure
(2) Scan Mode
<File Type>
Functions
• To set the file type of the data to be sent.
Use
• To set the file type of the data to be sent.
• The default setting is "TIFF".
Setting/
Procedure
Letter/Legal
"11x17"
200 dpi
400 dpi
"MH"
MR
"TIFF"
PDF
9. Utility/Counter Mode
"600 dpi"
MMR
133
Need help?
Do you have a question about the ineo 250 and is the answer not in the manual?
Questions and answers
how to resolve error code C3452
Error code C3452 indicates a Fusing Warm-Up Failure (Sub). It occurs when the Fusing Roller Sub Thermistor does not detect the required temperature within 30 seconds after a warm-up cycle begins, or the temperature does not reach the required level within the set time.
To resolve error code C3452:
1. Turn off the main power switch and allow the unit to cool down.
2. Check the Fusing Unit, especially the Sub Thermistor for damage or disconnection.
3. Inspect wiring and connectors between the thermistor and control board.
4. Replace the Sub Thermistor if faulty.
5. After repairs, reset the error code.
Ensure the fuser assembly is functioning normally before restarting the machine.
This answer is automatically generated