Maintenance Menu

Items in the maintenance menu

The following tables show the items in the maintenance
menu.
• Item names are the names which appear on the video
monitor of this unit and an external monitor to which the
output of the COMPOSITE OUTPUT 2 (SUPER)
connector, the SDSDI OUTPUT 2 (SUPER) connector,
or the HDSDI OUTPUT 2 (SUPER) connector is input.
• An abbreviated name appears in the time data display
area when you press the NEXT button.
Item
M30: SOFTWARE VERSION
M31: SERIAL NUMBER
M36: HOURS METER RESET
M37: AUDIO
M370: METER HEAD
CONFIG
ROOM
M371: DATA LENGTH
M372: NON-AUDIO
INPUT
Sub-item
1 Tr1/Tr2
2 Tr3/Tr4
3 Tr5/Tr6
4 Tr7/Tr8
M373: INPUT LEVEL
Sub-item
1 CH1/CH2
2 CH3/CH4
M377: OUTPUT LEVEL
M3B: VANC RX
M3BD: HD VANC INPUT For setting HD SDI ANC data input parameters
PARAMETER
M3BD: LINE
M3BD: DID
M3BD: SDID
M3C: POWER SAVE CONTROL
M3D: DATE/TIME PRESET
M3E: USB MEMORY UTIL
104
Maintenance Menu
• The values in the Settings columns are the values which
appear in the time data display area. (The values may
appear in a different format on an external monitor. In
this case, the external monitor values are shown in
parentheses.) Underlined values are the factory defaults.
For details about DRIVE MAINTENANCE, CHECK and
SERVICE SUPPORT, refer to the Maintenance Manual.
M3: OTHERS: Other setting items
Setting
Display of the software version of this unit
Display and correction of the serial number of this unit
Display and reset of the hours meter and the thread counter
Select the audio reference level (headroom).
20dB, 18dB, 16dB, 12dB, EBUL (1080-50i)
Select the audio quantization bit count and number of recording channels.
16x8 (16bit x 8ch): 16 bits × 8 channels
24x4 (24bit x 4ch): 24 bits × 4 channels
Select whether to handle digital audio signals as non-audio signals during
recording.
Audio (audio): Handle as linear PCM audio signals.
data: Handle as non-audio signals.
Set the upper limit for the signal level input to audio channels 1/3 or 2/4.
+4dB, 0dB, –3dB, –6dB, EBUL (1080-50i)
Set the reference level for audio output signals.
+4dB, 0dB, –3dB, –6dB, EBUL (1080-50i)
Specification of the HDSDI line number that contains the V-ANC data that you
want to receive
OFF, 9LINE to 20LINE
Specification of the DID of the V-ANC that you want to receive
00h-FFh
Specification of the SDID of the V-ANC that you want to receive
00h-FFh
Specification of whether to enable the power saving function
OFF, ON
Specification of the date and time
For installation of software upgrade packages