5. PROGRAMMING
Option
VIEW ON DEMAND
VIEW TIME WINDOW
"VIEW TIME WINDOW"
menu appears only if
an option other than
"Disabled" is selected in
"VIEW ON DEMAND"
VIEW OTHER ALARM

5.6.7 Configuring Upload / Download Remote Programming Access Permission

Using a PC computer, the PowerMaster can be configured (by upload/download) either locally or from remote via
PSTN telephone line or GPRS cellular communication.
Local programming can be performed by direct connecting the computer to the panel's serial port using the Remote
Programmer PC Software.
Remote programming via PSTN can be performed by using a modem and the same software. The modem dials to
the control panel and establishes a connection via PSTN using an agreed process. When connection is established,
the installer or Master installer can access the panel using the UL/DL access codes programmed in the
"PSTN UP/DOWNLOAD" menu – see table below. For further information refer to the "PowerMaster Remote
Programmer Software User's Guide".
Remote programming via GPRS is performed using a Visonic PowerManage server and related Remote Programmer
PC software. The PowerManage server sends an SMS message from a cellular modem to the Panel's SIM card
number. The panel checks the caller ID of the SMS sender and if identical with any of the two callers ID 1 or 2
programmed in the "GPRS UP/DOWNLOAD" menu (see table below), the panel initiates a GPRS connection with the
respective IP Receiver 1 or 2 (as configured in section 5.6.4 options 21 & 22). When connection is established, the
monitoring company can perform the upload/download procedure via the established secured GPRS connection. For
further information refer to the PowerManage User's Guide
In this section you can configure the access permissions (i.e. security codes and identification) and determine the
functionality of the upload/download procedures via PSTN and GPRS channels.
04:COMMUNICATION
Enter "6:UP/DOWNLOAD", select the menu to configure (see guidance above and in section 5.6.1), then refer to the
table below for configuration instructions.
Option
PSTN UP/DOWNLOAD
Remote access
50
Configuration Instructions
Note: To enter the e-mail addresses, to move the cursor and clear digits, use the "String
Editor's" keys as described in the table at the end of section 5.6.3.
By enabling the "On Demand View", you can determine during which arming modes (system
states) the "On Demand View" will be permitted. In the next option "VIEW TIME WINDOW"
you can determine when, during the permitted arming modes, the "On Demand View" will be
enabled.
Options: disabled (default); in all modes; in AWAY only; in HOME only; in HOME &
AWAY; DISARM & AWAY; DISARM & HOME; and in DISARM only.
If the "On Demand View" is enabled in the previous option, you can further determine whether
the "On Demand View" will be possible at any time during the selected arming modes (i.e.
"Always") or restricted only to a specific limited time window that follows an alarm event.
Options: Always (default); Alarm + 5 min.; Alarm + 15 min.; Alarm + 1 hour
Define whether the system will capture and forward image clips also upon occurrence of Non-
Burglary alarms (i.e. Fire, Duress, Emergency and panic).
Options: Enable (default); Disable.
  
6:UP/DOWNLOAD
Configuration Instructions
Configure the Upload/Download functionality via PSTN. The functionality is determined
through a sub-menu of the "PSTN UP/DOWNLOAD" option as shown below.
To program:
Press
to enter the "PSTN UP/DOWNLOAD" sub menu and then select and configure
each of the sub-menu options as shown below. When done, press
Enable or disable the remote access to the system. If disabled, the system cannot be
accessed remotely thereby inhibiting the Upload/Download and the Remote Control via
PSTN or GSM analog communication channels (see Chapter 7 in the User's Guide).
Options: enabled (default); disabled.
  