PowerMaster-10/30 G2 V15 Manual Updates
This addendum describes changes in features, functionality and interface of the PowerMaster system version 15. The
changes mentioned in this addendum are updates to the accompanying Installer and User Guides of version 13 of the
PowerMaster system.
The changes apply to the following features:
New devices
•
Abort Fire Time
•
Transport Protocol
•
24H Zone Report
•
Record Speech
•
Operation Mode
•
Smoke Siren Test
•
New Devices
The following new devices are now supported by PowerMaster version 15:
TOWER-30AM PG2, TOWER-30AM K9 PG2
•
CLIP PG2
•
KF-235 PG2
•
KP-160 PG2
•
GSD-441 PG2
•
GSD-442 PG2
•
GB-501 PG2
•
TMD-560 PG2
•
FLD-550 PG2
•
Abort Fire Time
This section is a new menu in the PowerMaster-10/30 G2 Installer's Guide - section 3.5.4
40:ABORT FIRE T.
The PowerMaster is able to provide an "abort interval" that starts upon detection of a Fire event. During this interval, the
buzzer sounds a warning but the siren remains inactive and the alarm is not reported. If the user disarms the system within
the allowed abort interval, the alarm is aborted.
The new menu allows configuration of the length of time allowed by the system to abort a Fire alarm.
Options: 00 (default)/30/60/90 seconds
UDP/TCP Protocol Selection
This section is a new menu in the PowerMaster-10/30 G2 Installer's Guide - section 3.6.3
TRANS. PROTOCOL
PowerMaster now offers a choice of IP protocol used to transfer data over the internet/GPRS.
Options: TCP (default); or UDP.
24H Zone Report
This section is a new menu in the PowerMaster-10/30 G2 Installer's Guide - section 3.6.4
66:24H ZONE RPRT (Applicable in UK only)
Define whether 24 hour (silent and audible) zones will function as normal 24 hour zones or as panic zones.
Options: audibl as panic; silent as panic; both as panic; and both burglary (default).
D-304271 PowerMaster-10/30 G2 Addendum