Testing The Gsm Module; User Settings - Visonic PowerMaster-10 Installer's Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaster-10:
Table of Contents

Advertisement

5. PROGRAMMING
Option
SHOW ALL DEVICES
SHOW RF PROBLEMS

5.9.3 Testing the GSM module

The PowerMaster enable to test the GSM module integrated inside the panel.
06:DIAGNOSTICS
Enter the "GSM/GPRS" menu, and press
PowerMaster will present the test result.
The following table presents the test result messages
Message
Unit is OK
GSM / GPRS is functioning correctly
GSM comm. loss
GSM/GPRS module does not communicate with the Panel
Pin code fail
Missing or wrong PIN code. (Only if SIM card PIN code is enabled.)
GSM net. fail
Unit failed with registration to local GSM network.
SIM card fail
SIM not installed or SIM card failure.
GSM not detected
GSM auto enroll failed to detect GSM/GPRS module.
No GPRS service
The SIM card does not have the GPRS service enabled.
GPRS conn. fail
Local GPRS network is not available or, wrong setting to GPRS APN, user and/or password.
PowerManage receiver cannot be reached – Check the Server IP
Srvr unavailable
IP not defined
Server IP #1 and #2 are not configured.
APN not defined
APN is not configured.
SIM card locked
After entering a wrong PIN code 3 consecutive times the SIM is locked. To unlock it enter a PUK
number. The PUK number cannot be entered by the control panel.
Denied by server
PowerManage denies the connection request. Check that the panel is registered to PowerManage

5.10 User Settings

This USER SETTINGS menu provides you with a gateway to the user settings through the regular user menus.
Refer to the PowerMaster User's Guide for detailed procedures.
Caution! If after having programmed the user codes the system does not recognize your installer code, this
indicates you must have programmed a user code that is identical with your installer code. If so, access the user
menu and change the code that is identical with your installer code. This will re-validate your installer code
1
The signal strength indications are as follows: "STRONG"; GOOD"; "POOR"; "1-WAY" (the device operates in 1-way
mode or, the "NOW" communication test failed); "NO COM." (no communication); "NOT TST" (results are shown
without any performed test); "NOT NET" [device is not networked (not fully enrolled)]; "NONE" (keyfob 24Hr result); or
"EARLY" (result of the last 24Hrs without statistics).
56
Instructions
Press
to test the selected device. The following screen will appear: "TESTING Zxx NNN".
While in the handheld devices test process, indicated by the corresponding display, for
example, "TEST KEYFOBS 01", press any key of the selected handheld device to initiate
the test.
At the end of the test process, the panel will present the devices' status: "Zxx:
24hr: <status>"
1
"Zxx: NOW: <status>"
Note: Refer to "SHOW ALL DEVICES" section for further information on device status.
You can view the devices status.
Note: This option is available only after testing process was done.
Press
to view the devices' status.
The following screens will appear: "Zxx: 24hr: <status>"
Use
to scroll between the device's families.
You can view only the devices which have RF problems.
Note: This option is available only after testing process was done.
Press
to view the devices' status.
The following screens will appear: "Zxx: 24hr: <status>"
Use
to scroll between the device's families.
  
GSM/GPRS
to initiate the GSM diagnostic test. Upon test completion, the
1
.
1
"Zxx: NOW: <status>"
1
"Zxx: NOW: <status>"
Description
D-303222 PowerMaster-10/30 G2 Installer's Guide
1
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powermaster-30

Table of Contents