5. PROGRAMMING
LINE PREFIX
DIAL METHOD

5.6.3 Configuring GSM-GPRS (IP) - SMS Cellular Connection

The GSM/GPRS module is capable of communicating with the Monitoring station receiver by GPRS, GSM Voice
(analog) or SMS Channels.
Each of the channels can be separately enabled or disabled to allow or prohibit the module from using it for the event
reporting. If all channels are enabled, the GSM/GPRS module will always try GPRS first. If fails, it will try GSM voice. If
fails, it will try any other possible method (PSTN Broadband) and only then it will try SMS. Disabling any of the GSM
channels will cause the module to use a different sequence than the one described above.
04:COMMUNICATION
Enter "2:GSM/GPRS/SMS", select the menu you wish to configure (see guidance above and in section 5.6.1), then
refer to the table below which provides you with detailed explanations and configuration instructions for each option.
Option
GPRS REPORT
GSM REPORT
SMS REPORT
GPRS APN
GPRS USERNAME
SIM PIN CODE
GPRS PASSWORD
NETWORK ROAMING
Previously known as
"FORCE HOME NTWK"
GPRS ALWAYS ON
Previously known as
"SESSION TIMEOUT"
GSM KEEP ALIVE
44
Enter the prefix digit (if necessary) for the system to access an outside telephone line.
Define the dialing method used by the PSTN dialer of the PowerMaster control panel.
Options: pulse and tone (dtmf) (default).
  
2:GSM/GPRS/SMS
Configuration Instructions
Define whether the system will report events to the Monitoring Stations' PowerManage
receivers via the GPRS (IP) Channel. For further information, see section 5.6.4 options 21 & 22.
Options: disable (default); enable.
Define whether the system will report events to the Monitoring Stations' Alarm Format
receivers via the GSM Voice (analog) Channel. For further information, see section 5.6.4
option 41.
Options: disable (default); enable.
Define whether the system will report events to the Monitoring Stations' SMS receivers via
the SMS Channel. For further information, see section 5.6.4 options 26 & 27.
Options: disable (default); enable.
Enter the name of the APN Access Point used for the internet settings for the GPRS (up to
40 digits string).
Note: To enter the APN Access Point, use the "String Editor" at the end of this section.
Enter the Username of the APN used for GPRS communications (up to 30 digits string).
Note: To enter the Username, use the "String Editor" at the end of this section.
Enter the PIN code of the SIM card installed in the GSM module (up to 8 numerical digits).
Note: To enter the numerical PIN code, use the numerical keyboard.
Enter the Password of the APN used for GPRS communications (up to 16 digits string).
Note: To enter the Password, use the "String Editor" at the end of this section.
You can force the SIM card to use only its "Home Network" and disable it from roaming to
other networks in case the Home Network cannot be found.
Options: roam disable; roam enable (default).
Define whether the control panel will stay continuously connected "enabled", via GPRS
communication, or disconnect "disabled" (default), after each report session.
Some GSM Service providers tend to disconnect the GSM connection if the user has not
initiated any outgoing telephone calls during the last 28 days. To prevent from disconnecting
the GSM connection, you can configure the system to generate a "keep alive" GSM call
every 28 days sending a test message either to the first SMS number (if exists) or
  
MENU you wish