Visonic PowerMaster-10 Installer's Manual page 41

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaster-10:
Table of Contents

Advertisement

5. PROGRAMMING
Option
51:PIEZO BEEPS
With Partition
disabled
51:PIEZO BEEPS
1
With Partition enabled
52:TROUBLE BEEPS
53:MEMORY PROMPT
54:LOW-BAT ACK
55:BACK LIGHT
56:SCREEN SAVER
With Partition
1
disabled
1
Refers to PowerMaster-30 G2 only
40
Configuration Instructions
Define whether the panel will sound the exit/entry warning beeps during exit and entry delays or
not. An additional option is to mute the warning beeps only when the system is armed "HOME".
Options: ON (default), OFF when home (default in USA) and OFF, and OFF exit home.
Note: When exit beeps are OFF, the happy (success) melody will still sound toward the end of
an exit delay.
The volume level of the exit / entry beeps can be modified by pressing the
the keypad to increase the volume, or by pressing the
Define whether the panel will sound the exit/entry warning beeps during exit and entry delays
or not. An additional option is to mute the warning beeps only when the system is armed
"HOME".
The control panel's display is: Def:P1
The pushbuttons
,
Pressing each button repeatedly will toggle between each option.
Options:
(enable beeps), H (OFF when home) h (OFF exit home) and
Notes:
When exit beeps are OFF, the happy (success) melody will still sound toward the end of an
exit delay.
The volume level of the exit / entry beeps can be modified by pressing the
the keypad to increase the volume, or by pressing the
Under trouble conditions, the panel sounder emits a series of 3 short reminder beeps once per
minute. Define whether to enable or disable this reminder beeping or just disable it at night.
The "night" hours are defined in the factory but are usually from 8 PM (20:00) until 7:00 AM.
Options: ON (default in USA); OFF at night (default) and OFF.
Define whether or not the user will receive "Memory" indication that an alarm has been activated.
Options: ON (default) and OFF.
You can activate or deactivate the "Low Battery Acknowledge" requirement from the user whose
keyfob's battery is low. For further information, see PowerMaster User's Guide Chapter 5.
Options: OFF (default) – acknowledge not needed; ON – acknowledge required.
Define whether the panel's back lighting will remain on at all times or will turn on only when a
key is pressed and turn off within 10 seconds if no further keystrokes are sensed.
Options: always ON and OFF after 10 sec (default).
The Screen Saver option (when activated) replaces the status display with
"POWERMASTER-10" / "POWERMASTER-30" display if no key is pressed during more
than 30 seconds.
You can activate the Screen Saver and determine whether the status display will resume
following any key press (refresh by Key) or by entering a code (refresh by Code). If refresh
by Key is selected, the first pressing of any key (except Fire and Emergency) will produce the
status display and the second press will perform the key function. For further information, see
the User's Guide, Chapter 1, "Screen Saver Mode".
Options: OFF (default); refresh by code and refresh by key.
Notes:
1. To comply with EN requirements, "refresh by code" must be selected.
2. For Fire and Emergency keys, the first key press will produce the status display and will also
perform the Fire/Emergency function.
P2
P3
, and
provide selection of the corresponding partitions.
D-303222 PowerMaster-10/30 G2 Installer's Guide
button on
button to decrease the volume.
(disable beeps).
button on
button to decrease the volume.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powermaster-30

Table of Contents