5.11 Factory Default

The FACTORY DEFLT menu enables you to reset the PowerMaster parameters to the factory default parameters. To
obtain the relevant parameters defaults, contact the PowerMaster dealer. Reset factory default parameters as follows:
Step 1
Select "09:FACTORY DEFLT"
menu
09:FACTORY DEFLT
Note: For PowerMaster with 2 installer codes, INSTALLER code and MASTER INSTALLER code, only the master
installer code enables to perform the factory default function.

5.12 Serial Number

The SERIAL NUMBER menu enables reading the system serial number and similar data for support purposes only. To
read the system serial number and other relevant data proceed as follows:
Step 1
Select "10:SERIAL NUMBER" menu
10:SERIAL NUMBER
– Reading the Serial Number
[1]
Enter the Installer Menu and select the "10:SERIAL NUMBER" menu (see section 5.2).
[2]
The control panel's first display is the system serial number. Upon each press of the
panel will display the following information respectively:
Panel HW version: The version of the panel's software
Panel SW version: The version of the panel's keypad and LCD software
The version of the LCD display
The version of the modem

5.13 Start UL/DL

Note: This option is only used during the installation of panels monitored by compatible Monitoring Stations.
The "START UL/DL" menu enables the installer to initiate a call to the upload/download server. The server uploads the
PowerMaster configuration to its database and can download predefined parameters to the PowerMaster. To perform
server upload/download proceed as follows:
Step 1
Select "11:START UL/DL" menu
11:START UL/DL
 – Performing Server Upload/Download
[1]
Enter the Installer Menu and select the "11:START UL/DL" menu (see section 5.2).
[2]
After pressing the
"COMMUNICATING" - If the UL/DL server telephone number was already defined (see section 5.6.4 "Configuring
Events Reporting to Monitoring Stations"), the PowerMaster display will read "COMMUNICATING" which is
displayed during the dialing process.
"TEL# NOT DEFINED" - If the UL/DL server telephone number was not defined (see section 5.6.4 "Configuring
Events Reporting to Monitoring Stations"), the PowerMaster display will read "TEL# NOT DEFINED" which is
displayed for approx. 30 sec. and is followed by a sad (failure) tune.
"DOWNLOADING" - If communication has been established between the PowerMaster control panel and the
upload/download server, the PowerMaster display will read "DOWNLOADING" which is displayed during the
dialing process.
1
Refers to PowerMaster-30 G2 only
D-303222 PowerMaster-10/30 G2 Installer's Guide
Step 2
Select "<OK> to restore"
<OK> to restore
Step 2
[1]
The control panel displays the system serial number
0907030000.
JS701950 K13.013
JS700421 v1.0.01
Panel ID: 100005

PYTHON:
Step 2
[1]
Press
COMMUNICATING
button, one of the following messages will appear on the control panel display:
Step 3
Enter Installer Code
ENTER CODE:
1
Step 3
[2]
5. PROGRAMMING
Step 4
Resetting of factory default
parameters is underway
PLEASE WAIT...
Step 3
[2]
to Step 1
button, the control
1
to Step 1
Step 5
 to Step 1
57