Partitioning; General Guidance - "Partitioning" Menu; Enabling / Disabling Partitions; Operation Mode - Visonic PowerMaster-10 Installer's Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaster-10:
Table of Contents

Advertisement

5. PROGRAMMING
 – Performing Server Upload/Download
"DIAL ATTEMPT" - If communication has failed between the PowerMaster control panel and the
upload/download server, the PowerMaster display will read "DIALATTEMPT FAIL" which is displayed for approx.
30 sec. and is followed by a sad (failure) tune.
"DOWNLOAD OK" - After the downloaded/uploaded process has been completed successfully, the PowerMaster
display will read "DOWNLOAD OK" which is displayed for approx. 30 sec. and is followed by a happy (success)
tune.
"DOWNLOAD FAILED" - If communication has been established between the PowerMaster control panel and
the upload/download server but the downloaded/uploaded process has failed, the PowerMaster display will read
"DOWNLOAD FAILED" which is displayed for approx. 30 sec. and is followed by a sad (failure) tune.

5.14 Partitioning

5.14.1 General Guidance – "Partitioning" Menu
This menu allows you to enable/disable partitions in the system (for further details, see APPENDIX B).

5.14.2 Enabling / Disabling Partitions

To enable or disable the partition feature, proceed as follows:
Step 1
Select "12:PARTITIONING" menu
12:PARTITIONING

5.15 Operation Mode

Note: The Operation Mode is applicable only in the UK, USA and Canada.
5.15.1 General Guidance – "Operation Mode" Menu
This mode allows you to select an operation mode for the control panel according to compliance standards
EN-50131, DD243 and BS8243. Pertinent menus are tailored for each compliance standard

5.15.2 Select between EN-50131, DD243 and BS8243

To select the desired operation mode, proceed as follows:
Step 1
Select "13:OPERATION MOD" menu
13:OPERATION MOD
Note: If "EN-50131" is selected, the control panel will operate according to the regular settings of the control panel.

5.15.3 BS8243 Setup

13:OPERATION MOD
Enter the "02:BS8243 SETUP " menu, and press
Option
01:DISARM OPTION
1
Refers to PowerMaster-30 G2 only
58
Step 2
Select whether to "Enable" or "Disable" Partitions
Disable
Step 2
Enter "01:SELECT MODE"
01 SELECT MODE
  
02:BS8243 SETUP
Configuration Instructions
Define when it is possible to disarm the system:
entry/BS devs (default) – By keypad after the entry delay has expired and if an alarm
occurred in the system. By keyfob or keyprox at all times.
Entry/all devs - During entry delay, when the system is armed AWAY, by all devices. When
not in entry delay by keyfob or keyprox only.
entry/DD devs - During entry delay, when the system is armed AWAY, by using the keyfob or
keyprox. Keypads cannot disarm at all.
anytime/all dev – At any time and by all devices.
1
Step 3
Select "EN-50131", "DD243" or
"BS8243"
EN-50131
to configure BS8243 compliance standard settings.
D-303222 PowerMaster-10/30 G2 Installer's Guide
Step 3
 to Step 1
Step 4
 to Step 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powermaster-30

Table of Contents