User Functions; Retrieving Factory Defaults; Serial Number; Calling Upload/Download Server - Visonic PowerMaxExpress Installer's Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaxExpress:
Table of Contents

Advertisement

WL SENSORS TEST
DIAG. TESTING
(Perform walk test)
BATHROOM
Z19 STRONG
DIA G. TESTING
FRONT DOOR
(alternating for 5 sec.)
Z1 POOR
LIVING ROOM
(alternating for 5 sec.)
Z2 OK
(Each time the OK button is pressed,
the next test result is displayed)
GPRS CONN. TEST
PLEASE WAIT...
UNIT IS OK
( )
When the OK button is pressed, the test result takes
*
between 15 sec. to 4 mins. before it is displayed,
depending on the severity of the failure.
See par. 4.10.1 for a complete list of possible
GSM/GPRS messages and par. 4.10.2 for a
complete list of possible Broadband Module messages.

4.11 USER FUNCTIONS

This mode provides you with a gateway to the user functions
through the regular user programming menu. You may:
 Program the 4 (private) telephone numbers
 Program user codes
 Enroll keyfobs
 Set the auto arm option
 Set arming time
 Set the squawk option
 Set the system time and time format
 Set the date and date format

4.12 RETRIEVING FACTORY DEFAULTS

If you want to reset the PowerMaxExpress parameters to the
factory default parameters, you should enter the installer
menu and perform the "FACTORY DEFLT" function, as
described in the right side illustration. To get the relevant
parameters defaults, contact the PowerMaxExpress dealer.
Note: For PowerMaxExpress with 2 installer codes,
INSTALLER code and MASTER INSTALLER code, only the
master installer code enables to perform factory default
function.

4.13 SERIAL NUMBER

The menu "13. SERIAL NUMBER" enables reading the
system serial number and panel ID for support purposes
only.

4.14 CALLING UPLOAD/DOWNLOAD SERVER

Note:
This option is only used during the installation of panels
monitored by compatible central stations.
28
(see fgure 4.1a)
10. DIAGNOSTICS
WL SIRENS TEST
S1
Example
of test
result
S1
display
S2
Example
PLEASE WAIT...
of test
result
S2
display
Note
STRONG/GOOD/POOR/
"NOT OK" (with siren
Example
No., S1 or S2 before) is
of test
displayed according to
result
the wireless siren signal
display
strength).
S1=siren 1. S2 = siren 2.
CPU = Control Panel Unit
= 2 way comm.
LAN CONNEC T. TEST
( )
*
PLEASE WAIT...
UNIT IS OK
Figure 4.10 - Diagnostic Test Flow Chart
NON-PARTITIONING ON LY
WL KEY PADS TEST
CPU
WAIT
K1
CPU=STRONG
CPU
PLEASE WAIT...
CPU=STRONG
K2
Note
STRONG/GOOD/POOR/
"NOT OK" (with key pad
No., K1 or K2 before) is
displayed according to
the wireless siren signal
strength).
K1=key pad1 K2=key pad2
CPU = Control Panel Unit
LAN RESET OPTION
( )
*
FACTORY DEFIN.
REBOOT: Resets the Broadband Module
FACTORY DEFIN:
Resets all LAN setting defnitions (does not
reset CentralStation IP defnitions).
Refer to the User Guide for detailed procedures.
Note: User functions are not available from the Installer
Mode in UK control panels.
Caution! If after having programmed the user codes the
system does not recognize your installer code, this
indicates you must have programmed a user code that is
identical with your installer code. If so, access the user
menu and change the code that is identical with your
installer code. This will re-validate your installer code.
Entering to/exit from the FACTORY
DEFLT menu is shown in figure 4.1a
This is a brief display after which all
the factory defaults are retrieved.
Panel ID is a unique number of the control panel that is used
for registering the PowerMaxExpress to IPMP when using
GPRS.
This option allows the installer to initiate a call to the
upload/download
PowerMaxExpress configuration to its data base and can
unload predefined parameters to the PowerMaxExpress.
D-303973 PowerMaxExpress Installer's Guide
K1
CPU
WAIT
CPU=STRONG
K2
CPU
CPU=STRONG
= 2 way comm.
REBOOT
12. FACTORY DEFLT
<OK> to restore
ENTER CODE:
PLEASE WAIT ...
server.
The
server
[installer code]
uploads
the

Advertisement

Table of Contents
loading

Table of Contents