4. PowerMaster-30 G2 INSTALLATION
EXTERNAL POWER CONNECTION
Connect the power adaptor to the front panel power connector.
Figure 4.9 – Power Cable Connection

4.10 Supplying Power to the Unit

Connect power to the PowerMaster-30 G2 temporarily (see Figure 4.9). Alternatively, you may power up from the
backup battery, as shown in Figure 4.10.
Disregard any "trouble" indications pertaining to lack of battery or lack of telephone line connection.
For Europe Safety Compliance:
a. The model shall be installed according to the local electrical code.
b. The circuit breaker shall be readily accessible.
c. The rating of the external circuit breaker shall be 16A or less.
d. The cables for the AC mains connection shall have an overall diameter of 13mm and 16mm conduit.
Please refer to Figure 4.10 "Battery Insertion".
Open battery compartment cover. Insert
one 6-battery pack or 8-battery pack and
connect its connector as shown.
A. Front unit
B. Battery cable
Figure 4.10 – Battery Insertion
D-303222 PowerMaster-10/30 G2 Installer's Guide
25