4.7 DUAL RS-232 Optional Module Mounting

The DUAL RS-232 is a Module that enables connection of any two simultaneous devices, such as Local PC
programming or GSM Module.
The GSM unit enables the PowerMaster-30 G2 system to operate over a cellular network (for details regarding the
GSM modem features and connections, refer to the GSM Modem installation instructions).
1. To install the DUAL RS-232 module into the control
panel, press it into the marked location (see Figure
4.7) until a click is heard.
2. Connect the flat cable (included in the module's
package) between the front panel and the DUAL
RS-232 receptacle.
Caution! The receptacle with strain relief clip is for
the front unit – do not connect it to the back unit!
3. Connect a local PC to the DUAL RS-232 module
connector (B) or (C), as shown in Figure 4.7.
D-303222 PowerMaster-10/30 G2 Installer's Guide
A. DUAL RS-232 Module
B. Connector for PC
C. Connector for GSM or PC
D. Back unit
E. Flat cable with one strain relief clip
F. Visonic PC cable
Figure 4.7 –Dual RS-232 Module Mounting