Advertisement

5. PROGRAMMING
Option
63:ZONE RESTORE
64:SYST.INACTIVE
1
65:TWO WAY VOICE
Send 2wv code
Voice <- -> C.S.
Ringback time
Ambient level
(Return)
Master Installer only for
Send 2wv code /
Voice <--> C.S. /
Ringback time
Send 2wv code
Voice <- -> C.S
Ringback time
Ambient level
66:24H ZONE RPRT
Applicable in UK only
Event Reporting Chart
To simplify the configuration of reporting system events to Monitoring Stations, the event messages are divided into 5
Event Groups as described in the following table below: Due to lack of space in the display, the following abbreviations
are used alrm, alrt, o/c" and all (i.e. all events).
Event Group
Abbr. Events Messages Reported
alrm
Alarms
Open/close
o/c
Alerts
alrt
Maintenance
-
Trouble
-
Note: "Alarms" group has the highest priority and "Alerts" group has the lowest priority.
The PowerMaster allows you also to select which event groups will be reported to each of the two Monitoring Stations.
The table below describes the available reporting options. The minus (-) symbol means "but/less/except" e.g. all(-alrt)
means all events except alerts. The asterisk () is a separator between event messages reported to Monitoring
Station 1 (C.S.1) and event messages reported to Monitoring Station 2 (C.S.2).
1
Refers to PowerMaster-30 G2 with voice option only
48
Configuration Instructions
Some Monitoring Stations require that following an alarm event from a specific zone, the
system will also report when the alarming zone has restored to normal.
Options: report enabled (default) and report disabled
The PowerMaster can report a "System Inactive" event message (CID event 654) to the
Monitoring Station if the system is not used (i.e. armed) during a predefined time period.
Options: report disabled (default); after 7/14/30/90 days.
You can configure the two way voice channel settings of the control panel
Send 2 WV Code: Define whether the system will send two-way voice code to the Monitoring
Station (to turn the Monitoring Station from data communication to voice communication
state) by using pre-selected SIA or Contact-ID communication format only.
Voice <--> C.S.: Select the timeout for 2-way voice communication with Monitoring Stations, or
enable the Monitoring Station to ring back for 2-way voice function. This option is applicable only
after reporting an event to the Monitoring Station for listening and speaking.
Ringback Time: Define the period during which the Monitoring Station can establish 2-way
voice communication with the control panel
A. Alarm type message was received by Monitoring Station.
B. Ring Back function was selected (see "Voice <--> C.S." sub menu above).
Ambient Level: Select the ambient noise level of the installation. If it is a relatively noisy
environment, set it to High (default setting). If it is a very quiet environment, set to Low.
Options: don't send (default); and send.
Options: disable (default); timeout 10/45/60/90 s; timeout 2 m; and ringback.
Note: If "ring back" is selected, you should select "disable report" for private telephone (see
Option "01:REPORT EVENTS"), otherwise the Monitoring Station will establish communication
1
with the control panel
(after an event occurrence) in the normal manner (and not after one ring).
Options: 1 (default)/3/5/10 minute(s).
Options: low (default); and high.
Define whether 24 hour (silent and audible) zones will function as normal 24 hour zones or as
panic zones.
Options: audibl as panic; silent as panic; both as panic; and both burglary (default).
Fire, Burglary, Panic, Tamper
Arming AWAY, Arming HOME, Disarming
No-activity, Emergency, Latchkey
Low-battery, AC failure
All other Trouble events not indicated above, e.g. Missing, Jamming, Communication Fail etc.
(after 1 ring), if:
D-303222 PowerMaster-10/30 G2 Installer's Guide
1
, as follows: