4.2 Connecting to the Telephone Line

Connect the telephone cable to the SET connector and connect the telephone line cable to the LINE connector
(through the desired wiring cable entry).
Note: The telephone cable should be no longer than 3 meters.
A. LINE
B. SET
C. Tel line wall jack
A. LINE
D. 8-position RJ-31X plug
B. SET
E. Brown
F. Red
C. RJ-31X cord
Phone wiring in the UK: Line terminals must be connected to pins 2 and 5 of the wall jack.
For all installations: If DSL service is present on the phone line, you must route the phone line through a DSL filter
(refer to MESSAGE TO THE INSTALLER on page 2 for further details).
D-303222 PowerMaster-10/30 G2 Installer's Guide
PHONE WIRING
PHONE WIRING IN NORTH AMERICA
G. Green
H. Gray
I.
RJ-31X jack
Figure 4.2 – Phone Wiring
4. PowerMaster-30 G2 INSTALLATION
J. Line from street
K. House phones
17