4. PowerMaster-30 G2 INSTALLATION
4.8 Optional Expander Module Mounting
The Expander module enables connection of speech
box, site external siren, site internal siren or strobe
and connection of wired detector to wired zones
The Expander module also enables connection of a
desired device to PGM (programmable) output that is
activated according to predefined conditions.
Mount the Expander module as shown in Figure 4.8a.
1. Press downward on the Expander module
(located in the back panel) between its 2 clips.
2. Connect the Expander module flat cable to the
front panel Expander receptacle.
Caution! The receptacle with strain relief clip is for
the front unit – do not connect it to the back unit!
A. 2 clips
B. Flat cable with one strain relief clip
1
Wired zones can be enrolled in any zone in the PowerMaster-30 G2 control panel from 01 to 64
22
1
.
Figure 4.8a
D-303222 PowerMaster-10/30 G2 Installer's Guide
–Expander Module Mounting