Connecting Power To The Control Panel - Visonic PowerMaster-10 Installer's Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaster-10:
Table of Contents

Advertisement

A. PGM output
Vmax=30v
Imax=100mA
B. Relay
Note: Do not use mains cable other than that supplied by the manufacturer (3 m long).

3.7 Connecting Power to the Control Panel

CONNECTING AC POWER TO CONTROL PANEL USING AC/AC TRANSFORMER
Connect the power cable and close the control panel as shown below. Electrical socket-outlet shall be installed near
the equipment and shall be easily accessible.
WARNING! DO NOT USE AN OUTLET CONTROLLED BY A WALL SWITCH.
Note: This equipment should be installed in accordance with Chapter 2 of the National Fire Alarm Code, ANSI/NFPA 72,
(National Fire Protection Association).
Connect the power adapter to the
power connector.
Figure 3.7a - Power Cable
Connection
D-303222 PowerMaster-10/30 G2 Installer's Guide
PGM AND ZONE WIRING
C. Device
D. External power supply 5 - 30VDC
E. Wired detector's Tamper
F. Wired detector's alarm or arming key
Figure 3.6b – PGM & Zone Wiring
3. POWERMASTER-10 G2 INSTALLATION
13