6.22 Recent Closure

Here you enable or disable the "recent closing" report,
that is sent to the central station if an alarm occurs within
2 minutes from the expiry of the exit delay.
The options are: recent close ON and recent close OFF
Upon selecting Location 21, the display will change to:
2 1 : R E C E N T C L O S E
Select the desired option as outlined in Para. 6.1 C above.

6.23 Remote Access

Here you give or deny permission to access the system
and exercise control from a remote telephone.
The options are: rem. access ON and rem. access OFF
Upon selecting Location 22, the display will change to:
2 2 : R E M O T E A C C E S S
Select the desired option as outlined in Para. 6.1 C above.

7. DEFINING OUTPUT PARAMETERS

7.1 Preliminary Guidance

A. Mode description
Here you select events and conditions under which the
PGM (programmable) output and X-10 devices will function.
There are two kinds of memory locations in this sub-mode,
each of which requires a different programming method:
& Multiple Choice Locations: these memory locations
allow you to choose one of several options (see C
below for programming method)
DE5450P

6.24 Downloader Code

Here you determine the 4-digit code used as a password
for downloading data into the PowerMax memory.
Upon selecting Location 23, the display will change to:
Enter the 4-digit code as outlined in Para. 6.1 D above.
Attention! Do not use "0000" - this code is invalid.
Having thus completed a full cycle of all 23 communication
parameters, you may now continue by defining output
parameters (see Section 7).
& Numerical Data Locations: these memory locations
Should you wish to get an overall view of the entire
process, refer to the programming chart in Figure 6.
You may even use the chart as your only guide along
the programming process, instead of going through
the written step-by-step procedure.
Figure 6. DEFINE OUTPUTS Flow Chart
2 3 : D O W N L O A D C O D E
To return to the installer's menu, click
<AWAY>. This will get you back to:
< O K > T O E X I T
You may now review and select any other
mode on the installer's menu (by clicking
<NEXT> or <BACK>).
accept digital data (a code, a time limit etc. - see D
below for programming method).
15