5. PROGRAMMING

5.7.4 Entering Daytime Limits

  
05:OUTPUS
Enter the "LOCKOUT TIME" menu and enter the daytime limits through which the PGM device will turn off, even when
the associated sensors are triggered.

5.7.5 PGM Output Configuration

Option
PGM: BY ARM AWAY
PGM: BY ARM HOME
PGM: BY DISARM
PGM: BY MEMORY
PGM: BY DELAY
PGM: BY KEYFOB
PGM: BY SENSOR
 Zone A Z:_ _
Zone B Z:_ _
Zone C Z:_ _
PGM:BY LINE FAIL
PGM:PULSE TIME
PGM:LOCKOUT TIME
 start – HH:MM A
 stop – HH:MM A
52
PGM DEVICES
Configuration Instructions
Determine to activate the PGM output upon arming Away / Home / Disarm.
Options: disable (default); turn ON; turn OFF; activate PULSE.
Determine to activate the PGM output upon registration of an alarm in the memory. The
output will restore to normal upon memory clearing.
Options: disable (default); turn ON; turn OFF; activate PULSE.
Determine to activate the PGM output during the Exit and Entry delays.
Options: disable (default); turn ON; turn OFF; activate PULSE.
Determine to activate the PGM output upon pressing the AUX () button of keyfob
transmitters configured to activate the PGM output. For further details, refer to the
configuration instructions of the AUX () button of the respective keyfobs' datasheets.
Options: disable (default); turn ON; turn OFF; activate PULSE; toggle
Determine to activate the PGM output upon activation of any one of up to 3 sensors
(zones) in the systems irrespective of whether the system is armed or disarmed.
To configure:
"
Press
to enter the
to program, for example "Zone A". If the zone was configured before, the display shows
the current zone number "(Z:xx)" and if not, the zone number will be blank ("Z:_ _"). To
configure the zone number, press
activate the PGM output and press
the other two options ("Zone B" and "Zone C") and repeat the above process.
When done press
Options: disabled (default); turn ON; turn OFF; activate PULSE; toggle
Note: If you select toggle, the PGM output will be turned on upon event occurrence in any
of these zones and will be turned off upon next event occurrence, alternately.
Determine to activate the PGM output following failure of the PSTN line
by line fail NO (default); by line fail YES.
Options:
Determine the PGM output pulse time. This value is the same for all events (by ARM
AWAY, by ARM HOME, by DISARM etc.) which were selected with "activate PULSE"
option.
pulse time 2s
Options:
Enter daytime limits between which PGM lighting devices controlled by sensors will be off,
even when the associated sensors are triggered.
  
LOCKOUT TIME
PGM: BY SENSOR"
sub menu and then select the Zone you wish
. Enter the Zone number (2 digits) you wish to
to confirm. To add another sensor, select any of
to return.
pulse time 30s; pulse time 2m; pulse time
(default);
D-303222 PowerMaster-10/30 G2 Installer's Guide
4m.

Advertisement