5.7 PGM Output

5.7.1 General Guidance

The "05:OUTPUTS" menu enables you to select events/conditions under which the PGM (programmable) output will
function and to select the internal siren or STROBE light (that will be activated according to system programming).
  
05:OUTPUS
Enter "PGM DEVICE 01", select the menu you wish to configure (see guidance above and in section 5.2), and then
refer to the table in section 5.7.5 for configuration instructions.

5.7.2 Open Collector States

The PowerMaster provides an open collector output (active low) for control:
ON state (pulled to ground) = 0
OFF state:
no pullup = float
with pullup to Vcc = 1

5.7.3 Configuring a PGM device

Define which factors, including any combination of factors, will determine the PGM output.
D-303222 PowerMaster-10/30 G2 Installer's Guide
Configuration Instructions
Enter the 4-digit password (Master Installer download code) code that will allow the Master
Installer to access the system remotely and upload/download data to the PowerMaster panel.
Note: "0000" is not a valid code and must not be used.
Enter the 4-digit password (Installer download code) code that will allow the Installer to
access the system from remote and upload or download data into the PowerMaster panel.
Notes:
"0000" is not a valid code and must not be used.
The installer can configure via UL/DL only the options he is authorized to configure from the
control panel.
Define whether the downloading/uploading can be performed in Disarm mode (state) only or
in all modes (i.e. Away, Home & Disarm).
Options: in all modes (default) or in DISARM only.
Enter the telephone number (up to 16 digits) of the UL/DL server.
Note: Only for use with control panels monitored by compatible monitoring stations. Leave
empty if not used.
Configure the Upload/Download functionality via GPRS. The functionality is determined
through a sub-menu of the "GPRS UP/DOWNLOAD" option as shown below.
To program:
Press
to enter the "GPRS UP/DOWNLOAD" sub menu and then select and configure
each of the sub-menu options as shown below. When done, press
Enter the PowerMaster SIM card telephone number. The PowerManage server at the
Monitoring Station sends an SMS message to this number for the panel to call back the
PowerManage server via GPRS for initiating the uploading / downloading process.
Enter the SIM card telephone number of the panel's GSM module.
Enter the "Caller ID" (i.e. telephone number) from which Monitoring Station #1 (C.S.1) /
Monitoring Station #2 (C.S.2) is supposed to send the SMS message to the control panel
for initiating the Up/Download process. If the sender's Caller ID matches with the "1
nd
ID#" / "2
caller ID#", the PowerMaster will call back the PowerManage server using
"IP RCVR 1" / "IP RCVR 2" address as configured in Section 5.6.4, options 21 and 22.
Note: Caller ID#1/ID#2 must contain at least 6 digits otherwise the process will not work.